Release Notes: CODESYS Control SL Extension Package 4.16.0.0

Key Issue Type Summary Resolution Note
RTSL-3261 Improvement

Linux SL products - change logger default settings

Fixed
RTSL-3239 Improvement

Redundant Time Provider

Fixed
RTSL-3062 Improvement

Linux packages (deb,rpm): restrict folder permissions for "other" users

Fixed [[GENERAL]]
Access to directories related to CODESYS .deb packages is now restricted for "other" users.

[[KNOWN_LIMITATIONS]]
CODESYS Control for PLCNext SL: working directory has not been restricted, because Phoenix firmware needs access for Axioline.
RTSL-3025 Bug

Extension API: UDS IO Driver doesn't support REAL/LREAL

Fixed [[GENERAL]]
IEC Input/Output channels of type REAL/LREAL can already be used.
All simple data types can be transported through the IEC IoDriver "IoDrvSocketUnix" by a conversion to 8/16/32/64 bit data types represented by USINT/UINT/UDINT/ULINT.
The python example "uds_io_driver.py" now contains a (commented) example to show how conversion can be done to handle floating point channels.
RTSL-3022 Bug

Deploy Tool: 2FA with key-based login fails on first try

Fixed