.
| Key | Issue Type | Summary | Resolution | Note |
|---|---|---|---|---|
| PN-665 | Improvement | GSDML Converter: Update safety-related documents for Tool Classification |
Fixed | |
| PN-641 | Bug | Profinet Controller (IEC): Connections Do Not Recover |
Fixed | |
| PN-639 | Bug | Profinet Controller (CIFX V3): RDREC / WRREC Show Invalid Error Codes |
Fixed | |
| PN-635 | Bug | Profinet (IEC) - RPC: NoCall - Reject Invalid |
Fixed | |
| PN-626 | Improvement | SafetyGSDMLConverter: Use LongPath-Utilities when creating files |
Fixed | |
| PN-622 | Bug | Profinet / RPC: Cycle Time of CommTask on RTE |
Fixed | |
| PN-619 | Improvement | Profinet Controller (CIFX V3): IO-Link Licence Check Message |
Fixed | |
| PN-611 | Bug | Profinet Controller (CIFX V3): Check Limit of DPM Data faulty |
Fixed | |
| PN-608 | Bug | Profinet Device (IEC): DeviceAR FB Shows Invalid Abort Code |
Fixed | |
| PN-606 | Bug | Profinet Controller (IEC): Corrupted PROFIsafe IO-Mapping |
Fixed | |
| PN-600 | Bug | Profinet (IEC): MRP Client sends invalid MRP Domain UUID |
Fixed | |
| PN-599 | Improvement | Improve information/message that the driver resets the network settings |
Won't Fix | [[GENERAL]] Das Verhalten ist so gewünscht und erforderlich. On eine Datei mit remanenten Daten vorhanden ist oder nicht spielt keine Rolle. In den remanenten Daten könnte auch die IP=0.0.0.0 stehen oder aber das "use temporary" flag, was wiederum bedeutet, daß das Gerät ohne Ip startet (gleiches gilt für den Sationsnamen). |
| PN-598 | Bug | Profinet Controller: ProfiSafeHost communication does not work any more |
Won't Fix | [[GENERAL]] Changes to Safety Solution require PN 4.5.0.0. |
| PN-597 | Bug | Profinet Controller: Reading Value of Record-Data Parameter Fails |
Fixed | |
| PN-595 | Bug | Profinet Controller (IEC): MRP Client sends no Topology Change |
Fixed | |
| PN-589 | Bug | Profinet Device (IEC): Legacy MRP-Configuration is Invalid |
Fixed | |
| PN-587 | Epic | Profinet/Profisafe: Support TCI |
Fixed | [[KNOWN_LIMITATIONS]] PN-640 |
| PN-581 | Improvement | Profinet Configurator / TCI: Device Tool Invocation |
Fixed | |
| PN-580 | Bug | Profinet Device (IEC): Topology Detection of non-PROFINET Switches |
Fixed | |
| PN-579 | Bug | Profinet Configurator: GSDML Import and DataType 'Date' / 'BinaryDate' |
Fixed | |
| PN-578 | Improvement | Profinet Controller: TCI Service Handler |
Fixed | |
| PN-577 | Improvement | Profinet Import: Support of Profisafe V2.6 GSDML files |
Fixed | |
| PN-576 | Bug | Profinet Device: DeviceAR FB may block Connection |
Fixed | |
| PN-574 | Improvement | Profinet Configurator: GSDML Import shall create Icon from Bmp |
Fixed | |
| PN-572 | Improvement | Profinet Device (IEC): Programatic Config lacks Option for MRP |
Fixed | |
| PN-564 | Bug | Profinet Configurator / Scan-Dialog: Gateway not Set |
Fixed | |
| PN-545 | Improvement | Change Vendor to CODESYS |
Fixed | |
| PN-539 | Bug | Profinet Configurator: MRP Configurator and Special Characters |
Fixed | |
| PN-527 | Improvement | PN Device/Module: Generate Text List from GSDML |
Duplicate | [[GENERAL]] duplicates PN-124 |
| PN-524 | Improvement | Profinet (IEC) / RTE: Enable 1GBit support in LLDP |
Fixed | |
| PN-428 | Improvement | Profinet Configurator: Upgrade GSDML Schema |
Fixed |